logo of serim

Products

HI-FOUNDATION

This is water tank base that holds two ends together as a connection by consisting of a rotating, height controlled type of steel support, an upper and a lower support plate.

HI-FOUNDATION

This is the foundation of a systematized water tank, constituted of a rotating, height-adjustable steel support and upper and lower backing plates, that connects each of their foundations and fixes both ends.

hitank_G_img1
hitank_G_img1
hitank_G_img2
hitank_G_img3

What is SERIM HI-FOUNDATION?

  It is a foundation of a systemized water tank which consists of a steel support with adjustable rotary height, a top and a bottom plate and both ends are fixed as a linkage for each foundation.

HI-FOUNDATION
  1  
  2-5  
  6  

1. General comparison between Concrete Foundation and Hi-Foundation

Description Concrete Foundation Hi-Foundation
Shape Concrete Foundation HI-FOUNDATION
Pad material Plain concrete + Steel liner STS pipe + SMC
Build Moulding-Concrete pouring
-Curing-Mortar plaster-Curing
Bolt assembling
Leveling Poor horizontality
(Non-precise standing of skid base)
Precise horizontality
(Precise standing of skid base)
Durability
(Strength)
Good compression strength,
but instabilities for curing,
plastering & liner
Standardized Uniform Quality
with more than 8times safety
ratio (Ready made product)
Corrosion
resistance
Rust on steel liner
Concrete corrosion
No rust
(Anti corrosion material)
Pad weight reduction
/ 300 places
165,600kg (100%) 3,600kg (2%)
Build time
/ 500 tons
More than 30days Less than 3days

2. Structural design and stability verification

  SERIM HI-FOUNDATION is a proven product that has undergone a field test for a scientific design and compressive strength test by FEM and a 7 meter high water tank.

3. FEM analysis result

FEM analysis model

HI-FOUNDATION generation stress

 Stiffener (Steel)

197kgf/cm² < 1600kgf/cm²
(Allowance rate 8.1 times)

 Stiffener Plate (SMC)

17kgf/cm² < 212kgf/cm²
(Design Margin 12.5 times)

4. Field Test

Water height Skid base deflection Spec (KS Standard)
7mH 1.25mm Less than 10.0mm
Maximum deflection 1.25mm
(strain safety factor 8 times)
Field Test

5. SERIM HI-FOUNDATION Pre-fabricated Structure

SERIM HI-FOUNDATION Pre-fabricated Structure

6. SERIM HI-FOUNDATION Construction procedure